Mobile Food Unit Water, Construction, And Utility Requirements
A mobile food unit (MFU) is a food establishment designed to be easily moved and used to prepare and sell food. Menu approval is based on the equipment available on the unit and, when required, at an approved commissary kitchen. All equipment must support safe food handling, storage, and preparation. Minimum construction and design standards are established in 15A NCAC 18A .2672.
Review Food Establishment Protection And Sanitation Rules (15A NCAC 18A .2600)
For More Information or Questions,
Please contact Environmental Health
Call 252-902-3200 or Email: pitt.envhealth@pittcountync.gov
Mobile Food Unit Construction & Interior Design Standards
The diagram above is an example mobile food unit equipment layout, not to scale. The layout illustrates typical food preparation, cooking, storage, and service areas, including sinks, service counters, refrigeration, cooking equipment under a vent hood, HVAC location, fan placement, propane tanks, and a generator mount.
Floors, Walls, and Ceilings
- Floors must be smooth, durable, nonabsorbent, and easy to clean.
- Walls and ceilings must be smooth, light-colored, nonabsorbent, and easily cleanable.
- All seams, joints, and corners must be sealed to limit moisture buildup and pest entry.
- Carpet, exposed wood, and unfinished surfaces are not approved in food prep or storage areas.
Ventilation and Exhaust Systems
- Cooking equipment that produces grease, smoke, or heat must be installed under an approved exhaust hood.
- Hoods must be properly sized and vented to the exterior.
- Ventilation systems must limit grease accumulation and excess heat inside the unit.
Doors, Windows, and Facility Openings
- Service windows must have tight-fitting doors, screens, or approved barriers to limit insect entry.
- Exterior openings must remain closed when not in use.
- Self-closing or screened doors may be required based on the unit’s design.
Equipment Installation, Storage, and Temperature Control
- Equipment must be securely installed to prevent movement during operation or transport.
- Spacing must allow for cleaning, maintenance, and safe operation.
- Equipment must be installed according to manufacturer specifications.
- Approved mechanical refrigeration is required for foods needing temperature control.
- Hot holding equipment must maintain required food temperatures.
- Portable coolers and similar containers may only be used for temporary holding.
Pest Control and Fire Safety
- The unit must be constructed to reduce the entry of insects, rodents, and other pests.
- Gaps, cracks, and utility penetrations must be sealed.
- Food and single-service items must be stored off the floor and protected from contamination.
- Cooking equipment must meet fire safety and clearance requirements.
- Propane tanks and fuel sources must be secured and located outside the food prep area.
- Fire suppression systems may be required based on cooking equipment used.
Mobile Food Unit Lighting Standards
- Lighting layout shows where light fixtures are located in the MFU, as well as how they are connected to the power source.
- Listing the type of light fixture with the maximum wattage is important for understanding the loading on the power source, and how what types of lights are proposed at specific locations.
- Light intensity (or how bright the light needs to be) that is required varies by designated use of a location, and minimum light requirements will be determined by review of the equipment layout and discussion with owner/operator.
- The lighting layout is not the same as the electrical layout.
- It is best to plan lighting to have the maximum brightness needed, but with the fewest light fixtures to minimize running conduits and cords. It is always recommended to consult a qualified electrician prior to making adjustments to lighting and electrical devices.
Minimum lighting levels include:
- 50 foot-candles at food preparation, cooking, and equipment-use surfaces
- 20 foot-candles at handwashing, dishwashing, storage areas, toilet rooms (if installed), and inside refrigerators
- 10 foot-candles in dry storage and other areas
- Food, utensils, and equipment must be protected from insects, dust, and environmental exposure.
- If cooking or food handling areas are exposed to outdoor conditions, protection such as a sneeze guard or enclosure must cover the front, top, and ends.
- Electric power must be supplied by an approved source such as a generator or direct connection.
- Generators must be properly sized to support all installed equipment, including refrigerators, freezers, pumps, lighting, ventilation, and cooking appliances.
- Generators should not be operated at maximum capacity for extended periods. Startup power and voltage requirements must be considered when selecting equipment.
Mobile Food Unit Plumbing Standards
- This layout is provided as an example only to outline basic plumbing requirements. It is not intended as a construction or installation guide. Plumbing design and installation should be completed by a qualified professional.
- Water tanks and hot water heaters must be sized to meet operational needs. Additional sinks or higher water demand may require larger capacity systems.
- If compressed air is used to pressurize the water system, an approved filter must be installed to prevent oil or vapor contamination.
- Potable water hoses must be approved for drinking water use and used only for that purpose.
- Water and wastewater tanks may be installed inside or outside the unit but must be designed to allow proper slope, venting, access for cleaning, and protection from damage.
- Tank vents must be protected with a 16-mesh screen or approved filter, especially when located in unprotected areas.
- All water inlets, outlets, and hoses must be protected from contamination using caps with keeper chains, enclosed cabinets, storage tubes, or other approved methods.
Water, Wastewater, and Servicing Conditions
- A pressurized potable water system is required, with hot and cold water available for food preparation, utensil washing, and handwashing.
- A dedicated handwashing sink is required and may only be used for handwashing.
- At least one warewashing sink is required and must be large enough to wash, rinse, and sanitize all utensils.
- Splash protection is required on walls and ceilings where water splash may occur.
- Wastewater may not be discharged while the unit is in motion. Waste tanks must include a shut-off valve and cap to prevent release.
- Water tanks must be durable, nonabsorbent, corrosion-resistant, smooth, easy to clean, fully enclosed, and sloped to allow complete drainage.
- If access ports are provided, they must be raised at least one-half inch and include a secured, gasketed cover that overlaps the opening.
- Tank inlets and outlets must be sloped for drainage, positioned to prevent contamination, and limited to a maximum diameter of three-fourths inch.
- Backflow prevention is required to protect water tanks, pumps, and hoses from contamination.
- The commissary must include a designated servicing area that supports mobile unit operations without impacting nearby properties.
- Portable coolers, Cambros, ice baths, and similar equipment may only be used for temporary hot or cold holding and are not approved for permanent food storage.